P filter for motor unit Versaflo. Protects against highly toxic dust ,mist and smoke particles. Saturation of the filter is only detectable by an increase in (inhaling) resistance, the motor unit will alarm.
Nova 3 hood, includes: NV3-750 nylon cape, NV2030 low flow indicator, NV2021B breathing tube, C40 constant flow air supply system with mail coupling CEJN 342, air conditioning unit
Comfortable half-mask made of elastomer, fitted with ergonomically formed head and neck bands for precise adjustment of the mask. With new improved expiration valve. Protects against organic gases and vapours with a boiling point >65 °C, plus toxic dust, vapour and smoke particles. Class 2 gas filter: for max. concentration of 0.5%. Sizes: universal. NPF: dependent on the filter used.
Dust mask, class P3, for toxic dust. Form-retaining mask thanks to Dura-Mesh shell on the outside of the mask. Mask always retains i ts shape, even when worn for extended periods or after folding the mask. Inside of mask features comfortable PE ring for more comfor t and better sealing. Exhalation valve provides lower exhalation resistance and low levels of CO2 and moisture in the mask. Valve fa ces downward to prevent fogging of glasses. Fitted with adjustable, elastic headbands with closure. NPF: 50.
Glass replacement lens for shot blasting helmet Panorama. Serves as the basic lens.
Lightweight breathing hood made of WEB 22 with PC visor. WEB 22 material captures particles, preventing the particles on the wearer from getting onto the work piece. Hood with double neck and shoulder protection so the inner hood can be tucked inside the clothing. Designed with innovative air guide that allows air to blow through 2 or 3 openings. Air channel leads to the visor to prevent it from fogging. Hood can be replaced separately. Can be used in combination with Jupiter motor unit or with compressed air via Flowstream regulator with air hose. For spray painting applications, special raw material of hood and visor can be cleaned with thinner. Weight: 315 g. NPF: 500 when used with Jupiter motor unit; 200 when used with compressed air.
Closet for breathing apparatus with one cylinder (up to 6,8l), aparatus can be put in the closet ready for use. For mural fixation. Dimensions: L:89cm,W:49cm,H:35cm. Weight: 5,7kg No PPE.
Fire-resistent seal for the head shell as accessory of hoods M-106, M- 107, M-306, M-307. No PPE.
Front seal as spare spart of hoods M-106, M-107. No PPE.
Escape hood offers protection for escape from chemical-polluted environments, it has a duration of 15 minutes and is a disposable de vice, to be disposed after use. It comes in a universal size. The bag is made of antistatic fabric with belt loops, ring for wall application and side rings for shoulder use. Te orange fluo hood is sealed in a vacuum bag and equipped with a wide panoramic anti-fogging visor, and elastic self-adjusting harness with an elastic tight collar. The silicone halfmask is anatomically shaped and designed ot fit perfectly. Version with ABEKP filter for protection agiainst dusts, fumes and mists, and organic and inorganic gasses and vapours, sulphur dioxide, hydrochloric acid and other gases, ammonia and its derivates. As well as smoke, fumes and dusts. Suitable for use in ATEX environments.
Automatic welding helmet from the 9100 series in durable, lightweight material. Good protection of ears and side of neck, and better coverage of the throat against heat and welding sparks with headband. Adjustable air stream. Cassette not included.
Complete kit with Speedglas heavy duty welding helmet G5-03 Pro Air grinding hood under welding hood, with welding filter G5-01/03 TW, Adflo particle filter and Adflo motor unit, and carrying bag. (without safety helmet adapter)
Intrinsically safe (Ex-proof) Li-ion battery 18V,3.0 Ah for SR 500 EX motor unit.
Fabric head harness for Cleanspace masks.
Welding lens attachment for 3S full face masks. Spatter and welding lenses not included. Dimensions: 90 x 110 mm.
Rubber hose with female and male standard threaded connection EN 148-1. Connects between filter and mask. Allows filter to be worn on the hip (in combination with separately supplied belt 1002677).
P1 R filter for usage on gas filter Moldex Moldex 9000 series or directly use on 7000 series halfmasks or 9000 series full mask. Protects against harmful dust, mist and smoke particles.
Front seal as spare spart of hoods M-306, M-307, M-406, M-407. No PPE.
High quality P3 dust filter from 3M for direct connection to 3M half and full face masks. Protects against toxic dust, mist and smoke particles. In plastic housing for extra protection against spatters.
Test liquid for performing fit test. Content: 55 ml.
Anti static rubber hoses offering outstanding aging qualities and longservice life. Resistance to sparks and scorching.CEJN safety couplings that are quickand easy to connect yet prevent accidental disconnection.
PVC hoses offering outstanding aging qualities and long service life. Resistance to sparks and scorching.CEJN safety couplings that are quick and easy to connect yet prevent accidental disconnection.
Replacement hood T-airline 1000 chem 1 (2 pieces).
Atex Filter adaptor when using the cleanspace large case filters PAF-37, PAF-0050 and PAF-0051, PAF-0052 and PAF-0077. No ppe.
Spare part for motorunit TR-800.
Pac of 10 pre filters for motorunit PX5.
Motor unit to be combined with all RPB hoods. Motor units eliminate breathing resistance, are suitable for beard and glasses wearers, do not cause allergic reactions and often protect better because there is a leakage from the inside to the outside. This makes them often a good alternative to dust, half and full masks. This motor unit is compact and light (1,150 kg), easy to clean, and can be combined with both dust and/or gas filters. Device equipped with a low flow/battery alarm. Not suitable for use in confined spaces. Includes: motor, 2 inch FR belt, cover for gas filter, flow meter, battery and charger and a pack of prefilters. NPF: Depends on hood used.
Air duct breathing hose for Speedglas Heavy Duty helmet G5-01. No PPE.
Device for practicing the use of the self-rescuer M20.2 Simulates weight and properties of the real units. Cost-effective solution to quickly train different people in the use of the self-rescuer. Extra mouthpieces available as an accessory.
Charger as accessory for motor unit Clean air Chemical.
Antistatic wipes, soaked with non-aggressive liquid, individually wrapped, for daily cleaning of Sundström products.
Output for 2 persons / compressed air hoses to be installed on Sundström filter system.
Protective film to protect the visor of the powered air hood from dirt and scratches.
Replacement filter for Adflo odour filter. Odour filter that removes unpleasant odours. Does not provide protection from gases or va pours, only improves comfort. If gas filters are already being used, it is unnecessary to use an odour filter. Can be used in combin ation with Adflo odour filter.
Full-face mask specially designed for the Cleanspace Work system, quick and easy fitting, wide panoramic visor, inner mask made of soft silicone. This mask is NOT suitable for use in ATEX environments.
Set of 2 hinge mechanisms for welding helmet G5-01.
CST half mask (including a CleanSpace CST head harness) is designed for use with the CleanSpace PRO Power Unit (CST1002) and CleanSpace ULTRA Power Unit (CST 1012).Made of soft silicone that moulds easily to the face and does not cause allergic dermatitis. Easy to attach to the power unit, the head harness easily attaches to the connection points and can be removed for cleaning.
Full-face mask specially designed for the Cleanspace CST system, quick and easy fitting, wide panoramic visor, inner mask made of soft silicone. This mask is NOT suitable for use in ATEX environments.
The CleanSpace CS3000WORK includes the following components: • 1 x CS3001WORK Motorized System • 1 x CS3009WORK Neck Support (Small) • 1 x CS3010WORK Neck Support (Medium) • 1 x CS3002WORK Standard TM3 P3 Particulate Filter • 1 x CS3008 Head Harness • 1 x PAF-1101 Battery Charger • 1 x CS3032 Carrying Bag • 1 x Quick Start Guide Does not come with a mask or fabric head harness.
Half-mask with integrated goggle and pre-filtted and replacebale A2P3 filter. Compact, lightweight and flexible design which adapts and fits perfectly to the face and offers a unique and innovative combined protection, reducing risks of non-compatibility, non-conformity and mist build-up. Large central non-return exhalation valve which reduces the breathing resistance for the user and keeps moisture build-up inside the mask to a minimum. Filters with low breathing resistance, increase the level of gas protection and have a longer life span.
Comfortable TPE half mask, with replaceable low profile ABEK1P3 filters. Protects against most organic and inorganic gases and vapours, sulphur dioxide, acidic gases and vapours, ammonia and organic ammonia derivatives, toxic dust, mist and smoke particles, and micro-organisms. Replacement filter: 1061777
Bitter test liquid for performing fit test. Content: 55 ml.
Air cooler with neoprene cover on belt for use in combination with 3M airhoods with bayonet coupling. With regulator to adjust the airflow and temperature in the air hood. Can cool air up to 28 °C. For use with compressed air hoses with max. length of 10 m. Brass warning whistle indicates when air flow is potentially too low. Hose to rubber of PU hood not included. All usable buttons are blue. Inlet pressure: 4 - 8 bar. Minimum airflow 170 l/min, max. 500 l/min. processes involving chemical risks. NPF: 50 with M-100 and 200 with all other usable air hoods.
Carrying case for Ultra Elite masks. Equipped with a handy shoulder strap. Ideal for the filter and mask to protect against dust. Dimensions: 318mm x 180mm x 232mm.
Full facial mask in very comfortable and high quality elastomer. Anti- vapor Polycarbonate visor with wide field of view. Fitted with EasyLock connection on the side of the mask for filters with similar connections: serie 9000. Without speaking membrane. The harness opens very widely, which makes it easy to put on the mask. Weight: 360g.
P3 R filter for usage on gas filter Moldex Moldex 9000 series or directly use on 7000 series halfmasks or 9000 series full mask. Protects against harmful dust, mist, ozon and smoke particles.
Cover for TR-600 can be combined with filter TR-6820E.
Secubox midi without symbol, blue. Dimensions: 236x225x120mm. With fixation material. No PPE.
Face seal for 9100 MP hoods. Not seperately certified as PPE.
Spare EX head harness for motorunits Cleanspace Ultra or Cleanspace EX.
Radiant heat cover to cover head and shoulders for airhoods M-300.
The 3M ™ Versaflo ™ BT-64 Breathing Hose is a heavier and more robust breathing hose with a fixed length to use for heavy work. This BT-64 Breathing Tube connects approved 3M close-fitting facepieces to 3M motor-powered systems to ensure clean air reaches the facepieces with unrestricted airflow. The breathing tube is supplied with the 3M ™ TR-973 Air Flow Indicator. The BT-953 cleaning and storage kit can be ordered separately. For use with 6000 and 7907S series full face masks, and 7500 series half masks in combination with the Versaflo TR-600 and TR-800.
Extension for the easy-to-clean belt for motor unitTR-600.
Charging station for 1 battery with power.
Breathing tube holder as a replacement part of G5-01 welding hood. No PPE.
P3 screw-on filter DIN 148 in plastic housing with reduced opening. Protects against toxic dust, mist and smoke particles. To be combined with half and full-face masks with standard threads or Proflow motor unit.
Protects against organic gases and vapours with a boiling point under 65 °C, low boiling point substances of class 1 and 2. For use in combination with full face masks with standard threads. Filter for one-time use only.
Complete kit with Speedglas heavy duty welding helmet G5-01, welding filter G5-01/03TW, Adflo particle filter, adflo motor unit and carrying case and consumables.
Odour filter that removes unpleasant odours. Does not provide protection from gases or vapours, only improves comfort. If gas filter s are already being used, it is unnecessary to use an odour filter. Can be used in combination with the Adflo motor unit. Suitable f or: processes involving chemical risks.
Belt for attaching hose to mask. In combination with hose with standard threaded connection, the filter can be worn on the hip to avoid high concentrations at filter input point during certain activities, e.g. opening a vat.
Particle-filtering preformed mask with exhalation valve. Additional activated carbon filter against odours, gases and vapours below threshold. Seamless headband and flexible, adjustable nose clip for a comfortable, secure fit. Comfortable sealing lip in nose area for secure fit. Exhalation valve to further reduce breathing resistance, by helping to minimise moisture build up inside the mask. Version : FFP 2 NR D preformed mask with valve and carbon. NPF 10 .EN 149 89/686/EEC