BE - +32 3 820 98 60 info@vdp.com
There are no products in your shopping basket.
Kit to connect Peltor hearing protection to the Versaflo hoods M-series.
Replacement cap T-airline 1000M x2.
Pouch to attach to belt 1057147.
Protection sleeve breathing hose Adflo. No PPE.
Belt for attaching hose to mask. In combination with hose with standard threaded connection, the filter can be worn on the hip to avoid high concentrations at filter input point during certain activities, e.g. opening a vat.
Complete disposable set, for very short work in an environment with asbestos, without direct relation to asbestos dust and without projection of asbestos (maintenance and repairs). It consists of an overall in size XL, a pair of PVC goggles, 1 FFP3 mask, and a pair of green nitrile gloves size 10, 1 waste bag with asbestos marking (90x110cm), a pair of disposable overboots and 1 roll of tape to stick gloves and overboots and thus prevent asbestos from penetrating the suit.
Test liquid for performing fit test. Content: 55 ml.
Set for performing a personal fit test for dust masks. Set contains test liquid, sprayer and hood. Test person puts on dust mask and hood, then the test liquid is sprayed inside the hood. If the wearer can taste the test liquid, the mask has not been fitted proper ly or the mask does not seal sufficiently for that person. Test can also be performed without hood.
Sweat band for air caps, S-133, S-333, S-433 and S-533.
Closet for breathing apparatus with one cylinder (up to 6,8l), aparatus can be put in the closet ready for use. For mural fixation. Dimensions: L:89cm,W:49cm,H:35cm. Weight: 5,7kg No PPE.
Harness to carry fan units SR500 EX on the back. No PPE.
Pre filter holder for fan unit SR500 EX.
Glass replacement lens for shot blasting helmet Panorama. Serves as the basic lens.
Bitter test liquid for performing fit test. Content: 55 ml.
Welding lens attachment for 3S full face masks. Spatter and welding lenses not included. Dimensions: 90 x 110 mm.
Sweatband Nomaz (pack 10 pcs), for headgear.
Radiant heat cover to cover head and shoulders for airhoods M-300.
Output for 2 persons / compressed air hoses to be installed on Sundström filter system.
Wire mesh visor for Commander shot blasting helmet. To be placed between basic glass lens and PC lens for added protection.
Speedglas braces compatible with the Caterpillar Compact Air and Barisoft belt.
Carrying case for Ultra Elite masks. Equipped with a handy shoulder strap. Ideal for the filter and mask to protect against dust. Dimensions: 318mm x 180mm x 232mm.
Adaptor to "park" lung demand valve Automaxx AS when not in use. Can be fixed on belt of bretahing apparatus.
Cover for TR-600 can be combined with filter TR-6820E.
Hose to connect C40 regulator with hood.
Device for practicing the use of the self-rescuer M20.2 Simulates weight and properties of the real units. Cost-effective solution to quickly train different people in the use of the self-rescuer. Extra mouthpieces available as an accessory.
Output for 2 persons / compressed air hoses to be installed on Aircare filter system.
Y-piece for installation on compressed air hose, with one male and two female couplings. With non-return valve, makes it possible to split 1 hose into 2 hoses. Fitted with Rectus 96 couplings (NOT compatible with Rectus 96 short of lung demand valves).
Replacement hood T-airline 1000 chem 1 (2 pieces).
The easy-to-attach fan reduces build-up and moisture from the 4000+ half masks (4251+,4255+,4277+,4279+), keeping you cool during long working days.
Extra mouth piece for trainer selfrescuer M20 devices.
Filter holder including strap to carry the filters of the half mask on the back, making the mask more compact and can be worn, for example, under a face shield.
PVC belt for remote filter holder (1058602).
Lightweight drawstring bag designed for convenience. Featuring two drawstrings attached to the bottom corners, it can be comfortably carried over the shoulder or as a backpack.
Carrying harness consisting of two shoulder straps and one hip belt to comfortably carry SSR30/100 B on the body in both the unopene d and opened position.
Changeover valve or automatic changeover valve for work that requires use of compressed air for breathing and where an interruption of the air supply could be life threatening. Changeover valve with one connection for air hose from compressed air line and one conn ection for air hose from compressed air apparatus. Primary source is the compressed air line and secondary source is the compressed air apparatus that functions as a backup if the supply from the air line is cut off. When the device is switched from the primary to the secondary source, a whistle sounds. For use with BD Mini, DB 96 and Airmaxx compressed air systems.
Sweat band for hoods from S-600 and S-700 series, and for S-950.
Fire resistant rescue hood that can be connected to the second terminal of a compressed air device. Once connected to the blower, the victim is supplied with fresh air. Visor treated against fogging. Is stored in a fire retardant and waterproof bag.
Communication adaptor for 3S-P mask.
Face seal speedglass 9100 air.
Dust filter holder for attachment of dust filters secure click series D7900 to 3M secure click gas filters. No PPE.
Filter holder.
Device for practicing the use of the self-rescuer M20.2 with hood. Simulates weight and properties of the real units. Cost-effective solution to quickly train different people in the use of the self-rescuer. Spare mouthpieces sold seperately.
To be installed on Sundström filter system.
Cleaning and storage plug set is designed for use with the CleanSpace WORK breathing air unit. It is an aid to seal all openings of the motor unit for storage. Do not carry the breathing apparatus when the plug set is in place. The plug set is made of polycarbonate and silicone.
Neck support for Cleanspace CST.
Cleaning and storage plug set is designed for use with the CleanSpace CST PRO breathing air unit. It is an aid to seal all openings of the motor unit for storage. Do not carry the breathing apparatus when the plug set is in place. The plug set is made of polycarbonate and silicone.
Neck support size small as a replacement part for Cleanspace Work.
Neck support size medium as a replacement part for Cleanspace Work.
Visor for air hood Simplair.
Welding lens attachment for Ultra Elite full face masks. Spatter and welding lenses not included. Dimensions: 90 x 110 mm.
Vaporiser to vaporise liquid in hood of fit test FT10.