• Home
  • Blog
  • Diphoterine® recertified: what do clinical trials say about water?

Diphoterine® recertified: what do clinical trials say about water?

Posted on 24.11.2026.

In 2026, Diphoterine® received a renewed Class IIa medical device certificate under the European Medical Device Regulation (MDR 2017/745). The main claim: It prevents or reduces the severity of chemical injuries more effectively than water, whether rinsing off takes place immediately or after a delay. The certificate is based on a clinical evaluation and a pre-clinical report from Prévor.

Chemical splashes can occur in an instant, and the actions you take immediately afterwards can make a significant difference to the severity of the injury. Water was the standard treatment for a long time. With this new certificate, an officially recognised claim has been established for the first time that a specialised rinsing solution performs better than water.

In this article, we explain what is new, what the certificate is based on, what the figures show and what remains unchanged.

 

What’s new?

A European notified body (GMED) has assessed the clinical documentation for Diphoterine® and confirmed its classification as a Class IIa medical device. The main claim is that Diphoterine® is more effective than water in preventing or reducing the severity of chemical injuries, regardless of whether rinsing takes place immediately (at the workplace) or after a delay (in hospital).

The claimed clinical benefits:

 

  • Less severe injuries when rinsing with Diphoterine® compared with water
  • Lower likelihood of surgery and prolonged hospital stay
  • Rapid pain relief

 

What is the certificate based on?

The certificate is based on two components:

 

  1. A clinical evaluation: A meta-analysis of the available publications, bringing together clinical outcomes in patients. According to Prévor, each publication was assessed by two doctors, the data was medically reviewed by four independent experts, and the statistical analysis was checked by external specialists.
  2. A preclinical report: which describes how a chemical injury develops and explains why Diphoterine® performs better than water.

 

Important to know: the review was carried out by Prévor and is a meta-analysis of published case reports, not a direct comparative trial.

 

What do the results show?

The meta-analysis compares 584 cases of skin injuries: 350 rinsed with water or saline solution and 234 with Diphoterine®. “Immediate” refers to rinsing at the workplace, while “delayed” refers to rinsing in hospital.

 

Criterion Timing Water or physiological saline Diphoterine®
Severe burns (deep second-degree or third-degree) Immediate 37.0 % 1.3 %
Severe burns (deep second-degree or third-degree) Delayed 48.0 % 5.3 %
Intensive aftercare (hospital stay longer than 15 days or skin grafting) Immediate 38.0 % 0.0 %
Intensive aftercare (hospital stay longer than 15 days or skin grafting) Delayed 50.0 % 3.0 %
Pain score after rinsing (scale of 0 to 10) Average 5.71 1.69

 

 

 

 

 

 

 

 

 

 

The findings for eye splashes are similar: injuries with a poor prognosis (Roper-Hall III and IV) occurred in 43.2 per cent of cases rinsed with water or saline solution compared with 17.5 per cent of cases rinsed with Diphoterine®. Intensive aftercare was required in 44.4 per cent of cases, compared with 3.6 per cent.

What stands out? With water, injury severity increases the longer it takes to rinse. With Diphoterine®, the results remain favourable even when rinsing is delayed. According to Prévor, results with Diphoterine® also vary less depending on the chemical substance, its concentration or the reaction time.

 

Why does Diphoterine® perform better than water?

Water works passively: it dilutes the chemical substance and removes what is present on the surface. Diphoterine® actively rinses: it removes the chemical substance from the surface and helps draw out any chemicals that have already penetrated the tissue. Preclinical data from Prévor show that this can help restore the tissue pH to the physiological range (between 5.5 and 9.0).

Preclinical research also shows that chemical injuries develop progressively. The process begins immediately after contact, but the damage does not become irreversible straight away. In a model using 50 per cent sodium hydroxide (the worst-case scenario), Prévor observed superficial cell damage after 60 seconds, a completely damaged epidermis after 1 hour, and necrosis of the epidermis and dermis after 2 hours. This means there is a therapeutic window in which intervention is possible, but it becomes narrower as time passes. Speed remains crucial.

 

What remains unchanged?

 

  • Medical follow-up is still necessary. Diphoterine® reduces the severity of the injury, but it does not always eliminate the need for further medical care.
  • Hydrofluoric acid (HF) remains an exception. Diphoterine® has limited effectiveness against HF. Use Hexafluorine® for this purpose.
  • Water and emergency showers are still necessary. For prolonged rinsing and in the event of thermal burns, emergency showers and eye wash stations remain the standard in accordance with EN 15154. If nothing else is available, always rinse immediately with water.
  • Shelf life: The products have a shelf life of two years and are intended for single use.

 

What does this mean for your organisation?

Less severe injuries can mean fewer absences and less disruption to work. In practical terms, there are three things you can do:

 

  1. Review your risk assessment: Is an active rinsing solution within easy reach for every risk involving corrosive or irritant substances?
  2. Position it close to the hazard: The first seconds and minutes make all the difference.
  3. Train your staff: Let them practise using the correct product formats for the eyes, hands, face and body.

 

Vandeputte can support you with your risk assessment, advise on product positioning, organise workshops and have a trade-in scheme for Prévor products. Interested in bespoke advice? Contact us

 

What you need to consider

 

  • In 2026, Diphoterine® received an updated certificate as a Class IIa medical device.
  • The main claim: It prevents or reduces the severity of chemical injuries more effectively than water, whether rinsing off takes place immediately or after a delay.
  • Prévor's clinical evaluation compares 584 cases of skin injuries and shows fewer severe burns and less need for intensive aftercare.
  • Rapid rinsing remains crucial, and medical follow-up is still necessary.
  • Use Hexafluorine® for HF exposure, and rinse with water if nothing else is available.

 

Frequently Asked Questions

 

What does Class IIa mean?
Class IIa is a risk classification for medical devices under the European Medical Device Regulation (MDR). The device has been assessed for safety and performance, and its claims must be supported by clinical evidence.

 

Is Diphoterine® now mandatory?
No. The certificate does not make the product mandatory. What you need depends on your risk assessment and the applicable regulations. Discuss this with your health and safety adviser.

 

What is a meta-analysis?
A meta-analysis combines the results of several studies to calculate an overall estimate. In this study, published cases involving rinsing with water or saline solution were compared with cases involving rinsing with Diphoterine®.

 

Does this also apply to hydrofluoric acid (HF)?
No. Use Hexafluorine® for HF exposure. Read more in our article on hydrofluoric acid.